FACTOID # 81: Two-thirds of the world's kidnappings occur in Colombia.
 
 Home   Encyclopedia   Statistics   Countries A-Z   Flags   Maps   Education   Forum   FAQ   About 
 
 
 
WHAT'S NEW
RECENT ARTICLES
More Recent Articles »
 

SEARCH ALL

FACTS & STATISTICS    Advanced view

Search encyclopedia, statistics and forums:

 

 

(* = Graphable)

 

 


Encyclopedia > Biosafety Level 4

The Centers for Disease Control and Prevention specifies four levels of biosafety precautions for biological agents. The most well-known Biosafety lab is USAMRIID (http://www.usamridd.army.mil/)(U.S. Army Research institute for infectious diseases.)


Biosafety Level 1 is suitable for work involving well-characterized agents not known to consistently cause disease in healthy adult humans, and of minimal potential hazard to laboratory personnel and the environment. The laboratory is not necessarily separated from the general traffic patterns in the building. Work is generally conducted on open bench tops using standard microbiological practices. Special containment equipment or facility design is neither required nor generally used. Laboratory personnel have specific training in the procedures conducted in the laboratory and are supervised by a scientist with general training in microbiology or a related science.


Biosafety Level 2 is similar to Biosafety Level 1 and is suitable for work involving agents of moderate potential hazard to personnel and the environment. It differs from BSL-1 in that

(1) laboratory personnel have specific training in handling pathogenic agents and are directed by competent scientists;
(2) access to the laboratory is limited when work is being conducted;
(3) extreme precautions are taken with contaminated sharp items; and
(4) certain procedures in which infectious aerosols or splashes may be created are conducted in biological safety cabinets or other physical containment equipment.

Biosafety Level 3 is applicable to clinical, diagnostic, teaching, research, or production facilities in which work is done with indigenous or exotic agents which may cause serious or potentially lethal disease as a result of exposure by the inhalation route. Laboratory personnel have specific training in handling pathogenic and potentially lethal agents, and are supervised by competent scientists who are experienced in working with these agents.


All procedures involving the manipulation of infectious materials are conducted within biological safety cabinets or other physical containment devices, or by personnel wearing appropriate personal protective clothing and equipment. The laboratory has special engineering and design features.


It is recognized, however, that some existing facilities may not have all the facility features recommended for Biosafety Level 3 (i.e., double-door access zone and sealed penetrations). In this circumstance, an acceptable level of safety for the conduct of routine procedures, (e.g., diagnostic procedures involving the propagation of an agent for identification, typing, susceptibility testing, etc.), may be achieved in a Biosafety Level 2 facility, providing

1) the exhaust air from the laboratory room is discharged to the outdoors,
2) the ventilation to the laboratory is balanced to provide directional airflow into the room,
3) access to the laboratory is restricted when work is in progress, and
4) the recommended Standard Microbiological Practices, Special Practices, and Safety Equipment for Biosafety Level 3 are rigorously followed.

The decision to implement this modification of Biosafety Level 3 recommendations should be made only by the laboratory director.


Biosafety Level 4 is required for work with dangerous and exotic agents that pose a high individual risk of aerosol-transmitted laboratory infections and life-threatening disease. Agents with a close or identical antigenic relationship to Biosafety Level 4 agents are handled at this level until sufficient data are obtained either to confirm continued work at this level, or to work with them at a lower level.


Members of the laboratory staff have specific and thorough training in handling extremely hazardous infectious agents and they understand the primary and secondary containment functions of the standard and special practices, the containment equipment, and the laboratory design characteristics. They are supervised by competent scientists who are trained and experienced in working with these agents. Access to the laboratory is strictly controlled by the laboratory director.


The facility is either in a separate building or in a controlled area within a building, which is completely isolated from all other areas of the building. A specific facility operations manual is prepared or adopted.


Within work areas of the facility, all activities are confined to Class III biological safety cabinets, or Class II biological safety cabinets used with one-piece positive pressure personnel suits ventilated by a life support system. The Biosafety Level 4 laboratory has special engineering and design features to prevent microorganisms from being disseminated into the environment.



See also:


External references:


  Results from FactBites:
 
Biosafety level - Wikipedia, the free encyclopedia (760 words)
Biosafety Level 1 is suitable for work involving well-characterized agents not known to consistently cause disease in healthy adult humans, and of minimal potential hazard to laboratory personnel and the environment.
Biosafety Level 3 is applicable to clinical, diagnostic, teaching, research, or production facilities in which work is done with indigenous or exotic agents which may cause serious or potentially lethal disease as a result of exposure by the inhalation route.
Biosafety Level 4 is required for work with dangerous and exotic agents that pose a high individual risk of aerosol-transmitted laboratory infections and life-threatening disease.
Safety Services - Biology (1354 words)
Biosafety Level 1 practices, safety equipment, and facilities are appropriate for undergraduate and secondary educational training and teaching laboratories, and for other facilities in which work is done with defined and characterized strains of viable microorganisms not known to cause disease in healthy adult humans.
Biosafety Level 2 practices, equipment, and facilities are applicable to clinical, diagnostic, teaching and other facilities in which work is done with a broad spectrum of indigenous moderate-risk agents present in the community and associated with human disease of varying severity.
Biosafety Level 4 practices, safety equipment, and facilities are applicable for work with dangerous and exotic agents which pose high individual risks from life-threatening diseases, which may be transmitted via the aerosol route, and for which there is no available vaccine or therapy.
  More results at FactBites »


 
 

COMMENTARY     


Share your thoughts, questions and commentary here
Your name
Your comments

Want to know more?
Search encyclopedia, statistics and forums:

 


Lesson Plans | Student Area | Student FAQ | Reviews | Press Releases |  Feeds | Contact
The Wikipedia article included on this page is licensed under the GFDL.
Images may be subject to relevant owners' copyright.
All other elements are (c) copyright NationMaster.com 2003-5. All Rights Reserved.
Usage implies agreement with terms, 1022, m