FACTOID # 150: The average person in the United Kingdom drinks as much tea as 23 Italians.
 
 Home   Encyclopedia   Statistics   Countries A-Z   Flags   Maps   Education   Forum   FAQ   About 
 
WHAT'S NEW
RELATED ARTICLES
People who viewed "FTIR" also viewed:
RECENT ARTICLES
More Recent Articles »
 

FACTS & STATISTICS    Simple view

  1. Select countries to view: (hold down Control key and click to select several)

     

     

    Compare:

     

     

  1. Select fact or statistic: (* = graphable)

     

     

     

  2. (OPTIONAL) Compare to statistic: (both need to be graphable)

     

     

     

  3. View result as:

     

       
(OR) SEARCH ALL encyclopedia, stats & forums:   

Encyclopedia > FTIR
Enlarge
FTIR of a thin film of ethanol in the liquid phase.

Fourier transform spectroscopy is a measurement technique whereby spectra are collected based on the response from a pulse of electromagnetic radiation. It can be applied to variety of types of spectroscopy including infrared spectroscopy (FTIR), nuclear magnetic resonance, and electron spin resonance spectroscopy. Fourier transform spectroscopy is more sensitive and has a much shorter sampling time than conventional spectroscopic techniques.


How it works

In a conventional (or "continuous wave") spectrometer, a sample is exposed to electromagnetic radiation and the response (usually the intensity of transmitted radiation) is monitored. The energy of the radiation is varied over the desired range and the response is plotted as a function of radiation energy (or frequency). At certain resonant frequencies characteristic of the specific sample, the radiation will be absorbed resulting in a series of peaks in the spectrum, which can then be used to identify the sample. (In magnetic spectroscopy, the magnetic field is often varied instead of the frequency of the incident radiation, though the spectra are effectively the same as if the field had been kept constant and the frequency varied. This is largely a question of experimental convenience.)


Instead of varying the energy of the electromagnetic radiation, Fourier Transform spectroscopy exposes the sample to a single pulse of radiation and measures the response. The resulting signal, called a free induction decay, contains a rapidly decaying composite of all possible frequencies. Due to resonance by the sample, resonant frequencies will be dominant in the signal and by performing a mathematical operation called a Fourier transform on the signal the frequency response can be calculated. In this way the Fourier transform spectrometer can produce the same kind of spectrum as a conventional spectrometer, but in a much shorter time.


The principles of the Fourier transform approach can be compared to the behavior of a musical tuning fork. If a tuning fork is exposed to sound waves of varying frequencies, it will vibrate when the sound wave frequencies are in "tune". This is similar to conventional spectroscopic techniques, where the radiation frequency is varied and those frequencies where the sample is in "tune" with the radiation detected. However, if we strike the tuning fork (the equivalent of applying a pulse of radiation), the tuning fork will tend to vibrate at its characteristic frequencies. The resulting tone consists of a combination of all of the characteristic frequencies for that tuning fork. Similarly the response from a sample exposed to a pulse of radiation is a signal consisting primarily of the characteristic frequencies for that sample. The Fourier transform is a mathematical technique for determining these characteristic frequencies from a single composite signal.


  Results from FactBites:
 
Fourier transform spectroscopy - Wikipedia, the free encyclopedia (794 words)
FTIR of a thin film of ethanol in the liquid phase.
Fourier transform spectroscopy is a measurement technique whereby spectra are collected based on measurements of the temporal coherence of a radiative source, using time-domain measurements of the electromagnetic radiation or other type of radiation.
There are several methods for measuring the temporal coherence of the light, including the continuous wave Michelson or Fourier transform spectrometer and the pulsed Fourier transform spectrograph (which is more sensitive and has a much shorter sampling time than conventional spectroscopic techniques, but is only applicable in a laboratory environment).
  More results at FactBites »


 

COMMENTARY     


Share your thoughts, questions and commentary here
Your name
Your comments
Please enter the 5-letter protection code

Want to know more?
Search encyclopedia, statistics and forums:

 


Lesson Plans | Student Area | Student FAQ | Reviews | Press Releases |  Feeds | Contact
The Wikipedia article included on this page is licensed under the GFDL.
Images may be subject to relevant owners' copyright.
All other elements are (c) copyright NationMaster.com 2003-5. All Rights Reserved.
Usage implies agreement with terms.