FACTOID # 157: People trust Swedes! Swedish companies are the world’s least-likely to be perceived as paying bribes.
 
 Home   Encyclopedia   Statistics   Countries A-Z   Flags   Maps   Education   Forum   FAQ   About 
 
WHAT'S NEW
RECENT ARTICLES
More Recent Articles »
 

FACTS & STATISTICS    Simple view

  1. Select countries to view: (hold down Control key and click to select several)

     

     

    Compare:

     

     

  1. Select fact or statistic: (* = graphable)

     

     

     

  2. (OPTIONAL) Compare to statistic: (both need to be graphable)

     

     

     

  3. View result as:

     

       
(OR) SEARCH ALL encyclopedia, stats & forums:   

Encyclopedia > Protection and monitoring of the electrical energy transmission networks

Whatever be the considered country, as far as it is large enough, the systems of electrical energy supply are meshed. They contain then three parts:


• the production units, i. e. the power plants, An electrical generator is a device that produces electrical energy from a mechanical energy source. ...


• the high voltage transmission network having in charge the transmission on great distances of important amounts of energy, and the synchronisation of the power plants, Transmission lines in Lund, Sweden Transmission towers and lines in Coquitlam, British Columbia. ...


• the middle and low voltage transmission network, having in the charge the supply of the customers. In one part or another, each asset may be the target of incidents, as failure, aberrant functioning, short circuit due to an external motive. So is installed a panoply of devices to avoid the destruction of the asset, or the cut of energy supply.Among them, we can distinguish 3 classes: The examples and perspective in this article or section may not represent a worldwide view. ...



• the protective relays which control the tripping of the circuit breakers framing the idle part of the asset or of the network, Automotive style miniature relay A relay is an electrical switch that opens and closes under control of another electrical circuit. ...


• the automatons, having in charge automatic operations, as reclosing or restarting,


• the monitoring equipment which collect some information on the assets and send them to the staff having in charge the control of the system The operating quality of these devices, and especially of the protective relays, is always capital. However it can be appraised differently as well as we consider either a part or another of the system.


Protection of the generator sets


In a power plant, the protective relays have to avoid the deterioration of the alternators or of the transformers in case of bad condition operation, due to internal failures, as well as insulating shortcomings or regulation disfunctioning. Such failures are unusual, and on well designed, wel manufactured, well installed, well maintained and well employed gears the protective relay have to operate very rarely. If a protective relay fails to detect as disfunctioning, the damage to the alternator or to the transformer may have important financial consequences. But these consequences remain internal to the utility: repair of the damaged asset , and loss of production, which must be replaced by more expensive production means - as well as the utility has available production means already synchronised to the network-.



Protection of the assets of the high voltage transmission network


On the high voltage transmission network, the issue is quite different : Firstly, an overhead line, which runs on the public domain, is periodically the target of short circuits, due to lightnings, unpruned trees, cranes or great hight engins working in the neighbourhood, wind, polution. A good design of the line may lower their probability, but not remove them. E. g. , on the network of the Electricité de France, an average of 7 short circuits per year and per 100 km may be observed. Secondly, when the temperature of a line increases, it becomes longer, and its lowest point, between two towers, fall away. If the line is not tripped in time, it becomes dangerous for the persons. The consequences must be then evaluated no more in millions of euros, but in lost of human lives ! And that is why the protection systems must include back-up functions : The failure of a relay is palliated by the back-up operation of relays may be located on other points of the network. This can lead to the tripping of many assets. The supply of an whole region can be jeopardised. A false operation of a protective relay may then provoke the tripping of one or several customers, may be an whole town, comprising the prioritar customers (hospitals, traffic lights, …). So, when a manufacturer consuming 10 MW is cut during 6 minutes, e.g., this coresponds not only to 1 MW of non selled energy, but top the non-selled energy during the time, may be several hours, necessary to restart the manufacture. But this corresponds to a dissatisfied customer, which lost several hours of his production, and may be underwent some deterioration on his equipment. If the matter is the tripping of a town, the supplyer must account for the failure, as public utility, to local, or even regional or national, authorities


Protection of the assets of the middle and low voltage networks


On these networks, the same considerations may be applied, but the consequences of a maloperation are not so important.



To have more information


You may consult the website •* [protection and monitoring of the electrical energy transmission network] on which the operating principles of the different devices used on the transmission networks are described, as well as their installation modality and the reckoning of their setting. The information contained in this website is essentially issued from an experience coming from an experience gathered on the network of the Electricité de France. But you can find also some information coming from audits in other countries, as well as from international working groups (CIGRE, IEEE). A few information is also available on the protection of generators. On the other hand, the protection of the middle and low voltage networks is not approached..


category: technology/list of engineering topics/electric power transmission



 

COMMENTARY     


Share your thoughts, questions and commentary here
Your name
Your comments
Please enter the 5-letter protection code

Want to know more?
Search encyclopedia, statistics and forums:

 


Lesson Plans | Student Area | Student FAQ | Reviews | Press Releases |  Feeds | Contact
The Wikipedia article included on this page is licensed under the GFDL.
Images may be subject to relevant owners' copyright.
All other elements are (c) copyright NationMaster.com 2003-5. All Rights Reserved.
Usage implies agreement with terms.