Most recent SCSI enclosure products support a protocol called SCSI Enclosure Services (SES). The initiator can communicate with the enclosure using a specialised set of SCSI commands to access power, cooling, and other non-data characteristics. In SCSI computer storage, an initiator is the host-side endpoint of a SCSI session. ... In SCSI computer storage, a command is the basic unit of communication. ...

Contents


SES devices

There are two major classes of SES devices:


Attached enclosure services devices allow SES communication through a LUN within one SCSI disk-drive located in the enclosure. The disk-drive then communicates with the enclosure by some other method, the only commonly used one being Enclosure Services Interface (ESI). In fault-tolerant enclosures, more than one disk-drive slot has ESI enabled to allow SES communications to continue even after the failure of any of the disk-drives. The definition of the ESI protocols is owned by an ANSI committee and defined in their specification ANSI SFF-8067 . The American National Standards Institute (ANSI) is a private, non-profit standards organization that produces industrial standards in the United States. ...


Standalone enclosure services devices have a separate SES processor which occupies its own address on the SCSI bus. The protocol for this uses direct SCSI commands. Fault-tolerance can be achieved by having two SES processors in the same enclosure.


SES commands

The SCSI initiator communicates with an SES device using two SCSI commands, Send Diagnostic and Receive Diagnostic Results. Some universal SCSI commands such as Inquiry are also used to perform basic functions such as initial discovery of the SES device. The SCSI Send Diagnostic command is used to instruct a target device to perform a self-test. ... The SCSI Inquiry command is used to obtain basic information from a target device. ...


SES elements

The SCSI Send Diagnostic and Receive Diagnostic Results commands can be addressed to a specific SES element in the enclosure. There are many different element codes defined to cover a wide range of devices. The most common SES elements are power-supply, cooling-fan, temperature-sensor and UPS. The SCSI command protocols assume that there may be more than one of each device type so they must be each given an 8-bit address. An uninterruptible power supply, or UPS, is a device or system that maintains a continuous supply of electric power to certain essential equipment that must not be shut down unexpectedly. ...


When a SES controller is interrogated for the status of a SES element, the response includes a 4-bit element status code. The most common element status codes are: 1h=OK, 2h=critical, 3h=warning, 5h=not installed.


SES element thresholds

Some SES elements like voltage sensors, current sensors, and temperature sensors support thresholding. This allows an enclosure to detect and report unacceptable environmental conditions. The SCSI standard allows for two different threshold levels, noncritical (warning) and critical. Also, each threshold has a minimum and maximum value. So for example the threshold values for the 12 volt power-supply could be set as follows:

  • Minimum critical - 10.8 volts
  • Minimum noncritical - 11.4 volts
  • Maximum noncritical - 12.6 volts
  • Maximum critical - 13.2 volts

Threshold values are set by a Send Diagnostic command to the Threshold Out diagnostic page (05h). Threshold values can be interrogated by a Receive Diagnostic Results command to the Threshold In diagnostic page (05h) with the PCV bit set to one.


Subenclosures

A larger SCSI storage enclosure may contain multiple subenclosures. The subenclosure with address 00h is designated the primary subencolusre and can return information about the other subenclosures.


External Links



 

COMMENTARY     


Share your thoughts, questions and commentary here
Your name
Your comments
Please enter the 5-letter protection code

Want to know more?
Search encyclopedia, statistics and forums:

 


Lesson Plans | Student Area | Student FAQ | Reviews | Press Releases |  Feeds | Contact
The Wikipedia article included on this page is licensed under the GFDL.
Images may be subject to relevant owners' copyright.
All other elements are (c) copyright NationMaster.com 2003-5. All Rights Reserved.
Usage implies agreement with terms.