A static inverter station is the terminal equipment for a high voltage direct current transmission line, in which direct current is converted to three-phase alternating current, and, usually, the reverse. Besides the static inverter itself, the station will also contain: HVDC or high-voltage, direct current electric power transmission systems contrast with the more common alternating-current systems as a means for the bulk transmission of electrical power. ... An inverter is an electronic circuit for converting direct current (DC) to alternating current (AC). ...

Contents

Figure 1:Three-phase pole-mounted step-down transformer. ... Capacitors: SMD ceramic at top left; SMD tantalum at bottom left; through-hole tantalum at top right; through-hole electrolytic at bottom right. ... A synchronous condenser is fundamentally an AC synchronous motor that is not attached to any driven equipment. ... Television signal splitter consisting of a hi-pass and a low-pass filter. ...

Components

Direct current switchgear

The direct current equipment often includes a coil (called a reactor) that adds inductance to help smooth the direct current. The inductance amounts to between 0.1 H and 1 H. The smoothing coil can have either an air-core or an iron-core. Iron-core coils look like oil-filled high voltage transformers. Air-core smoothing coils resemble, but are considerably larger than, carrier frequency choke coils in high voltage transmission lines and are supported by insulators. Air coils have the advantage of generating less acoustical noise than iron-core coils, they eliminate the potential environmental hazard of spilled oil, and they do not saturate under transient high current fault conditions. This part of the plant will also contain instruments for measurement of direct current and voltage. An inductor is a passive electrical device employed in electrical circuits for its property of inductance. ... Inductance (or electric inductance) is a measure of the amount of magnetic flux produced for a given electric current. ... An inductor. ... This article or section is in need of attention from an expert on the subject. ... For alternate meanings see Short circuit (disambiguation) A short circuit (sometimes known as simply a short) is a fault whereby electricity moves through a circuit in an unintended path, usually due to a connection forming where none was expected. ...


Special direct current filters are used to eliminate high frequency interference. Such filters are required if the transmission line will use power line carrier techniques for communication and control, or if the overhead line will run through populated areas. These filters can be passive LC filters or active filters, consisting of an amplifier coupled through transformers and protection condensers, which gives a signal out of phase to the interference signal on the line, thereby cancelling it. Such a system was used on the Baltic Cable HVDC project. SCADA is the acronym for Supervisory Control And Data Acquisition. ... The Baltic-Cable is a HVDC power line running beneath the Baltic Sea that interconnects the electric power grids of Germany and Sweden. ...


Inverter

The inverter is usually installed in a building called the valve hall. Since the mid 1970s solid-state devices such as thyristors are used. Many thyristors are assembled into a module, the thyristor tower. The thyristor towers can stand on insulators on the floor or hang from insulators from the ceiling. Thyristor inverters require voltage from the AC network for commutation, but insulated gate bipolar transistors used in some HVDC designs can provide power to a de-energized AC system. A valve hall is a building which contains the static power converter valves of a HVDC plant. ... The thyristor is a solid-state semiconductor device similar to a diode, with an extra terminal which is used to turn it on. ... The Insulated Gate Bipolar Transistor combines the simple gate drive characteristics of the MOSFET with the high current and low saturation voltage capability of bipolar transistors by combining an isolated gate FET for the control input, and a bipolar power transistor as a switch, in a single device. ...


Inverter transformer

The inverter transformers step up the voltage of the AC supply network. By using a star-delta (US: wye-delta) connection, the inverter can operate with 12 pulses in each cycle of the AC supply, which eliminates numerous harmonic current components. The insulation of the transformer windings must be specially designed to withstand a large DC potential to earth. Inverter transformers can be built as large as 300 MVA as a single unit. It is impractical to transport larger transformers so when larger ratings are required, several individual transformers are connected together. Either two three-phase units or three single-phase units can be used. With the latter variant only one type of transformer is used, making the supply of a spare transformer more economical. Figure 1:Three-phase pole-mounted step-down transformer. ...


Inverter transformers operate with high flux densities, and so produce more acoustic noise than normal three-phase power transformers. This effect should be considered in the siting of an HVDC static inverter plant. Noise-reducing enclosures may be applied.


Reactive Power

A static inverter will require between 40 and 60% of its megawatt rating as reactive power. This can be provided by banks of switched capacitors or by synchronous condensers. The demand for reactive power can be reduced if the inverter transformers have on-load tapchangers, with a sufficient range of taps for ac voltage control. Some of the reactive power requirement can be supplied in the harmonic filter components. A synchronous condenser is fundamentally an AC synchronous motor that is not attached to any driven equipment. ...


Filter for harmonics

Filter for harmonics are necessary for the elimination of the harmonic waves and for the production of the necessary reactive power. At plants with six pulse inverters complex harmonic filters are necessary, because there are odd-number harmonics from the 5th order upwards. At 12 pulse static inverter plants, only harmonic waves of the order 12*n + 1 and 12*n - 1 (n = natural number) result. Filters are tuned to the expected harmonic frequencies and consist of series combinations of capacitors and inductors.


Beside the harmonic filters, equipment is also provided to eliminate spurious signals in the frequency range of power-line carrier equipment, in the range of 30 kHz to 500 kHz. These filters are usually near the alternating current terminal of the static inverter transformer. They consist of a series coil which passes the load current, with a parallel capacitor to form a resonant circuit.


AC switchgear

The three-phase alternating current switchgear of a static inverter station is similar to that of an AC substation. It will contain circuit breakers for overcurrent protection of the converter transformers, isolating switches, grounding switches, and instrument transformers for control, measurement and protection. The station will also have lightning arresters for protection of the AC equipment from lightning surges on the AC system. A 115 kV to 41. ... A 2 pole miniature circuit breaker A circuit breaker is an automatically-operated electrical switch designed to protect an electrical circuit from damage caused by overload or short circuit. ... A lightning rod is a metal strip or rod, usually of copper or similar conductive material, used to protect tall or isolated structures (such as the roof of a building or the mast of a vessel) from lightning damage. ... This article needs additional references or sources for verification. ...


Others

Required area

The area required for a static inverter plant with a transmission rating of 600 megawatts and a transmission voltage of 400 kV is approximately 300 x 300 metres (1000 x 1000 feet). Lower-voltage plants may require somewhat less ground area, since less air space clearance would be required around outdoor high-voltage equipment.


Location factors

Static inverter station produces acoustic noise and radio-frequency interference signals. Walls may be built for noise protection. As with all AC substations, oil from electrical equipment must be prevented from contaminating ground water in case of a spill. Substantial land area may be required for transmission line entry and exit if overhead conductors are used, but this space can be reduced if connections are made by cable.


  Results from FactBites:
 
UPS Systems in Industrial Applications (3935 words)
Since the inverter supplies power to the load at all times and the battery is in parallel with the inverter input, when a power failure occurs the rectifier/charger merely stops operating and the battery picks up the load instantly, resulting in no power interruption at all.
Regulating the DC bus to the static inverter improves reliability by limiting the inverterÃ…s exposure to low voltage excursions (since voltage and current have inversely proportional relationships, low voltage on the inverter input means increased input current which can cause premature thermal failure of the semiconductors in the inverter bridge circuit).
The static transfer switch is a critical component with respect to load "uptime" as it allows an unbroken transfer of the load from inverter to alternate source and vice versa in the event of overcurrent, inverter failure or removal of the UPS from service for maintenance.
Static inverter plant - definition of Static inverter plant in Encyclopedia (829 words)
A static inverter station is the terminal equipment for a high voltage direct current transmission line, in which the transformation takes place from three-phase alternating current in direct current (and in reverse).
The static inverter transformers serve not only for the adjustment the voltage of the three-phase current supply, but also, by using a star-delta (US: wye-delta) connection, for the elimination of numerous harmonic currents components.
The area required for a static inverter plant with a transmission rating of 600 megawatts and a transmission voltage of 400 kV is approximately 300*300 metres.
  More results at FactBites »


 

COMMENTARY     


Share your thoughts, questions and commentary here
Your name
Your comments
Please enter the 5-letter protection code

Want to know more?
Search encyclopedia, statistics and forums:

 


Lesson Plans | Student Area | Student FAQ | Reviews | Press Releases |  Feeds | Contact
The Wikipedia article included on this page is licensed under the GFDL.
Images may be subject to relevant owners' copyright.
All other elements are (c) copyright NationMaster.com 2003-5. All Rights Reserved.
Usage implies agreement with terms.