Encyclopedia > Voltage standing wave ratio

In telecommunication, standing wave ratio (SWR) is the ratio of the amplitude of a partial standing wave at an antinode (maximum) to the amplitude at an adjacent node (minimum).


The SWR is usually defined as a voltage ratio called the VSWR, for voltage standing wave ratio. It is also possible to define the SWR in terms of current, resulting in the ISWR, which has the same numerical value. The power standing wave ratio (PSWR) is defined as the square of the SWR.


The voltage component of a standing wave in a uniform transmission line consists of the forward wave (with amplitude Vf) superimposed on the reflected wave (with amplitude Vr).


Reflections occur as a result of discontinuities, such as an imperfection in an otherwise uniform transmission line, or when a transmission line is terminated with other than its characteristic impedance. The reflection coefficient ρ is defined thus:

.

ρ is a complex number that describes both the magnitude and the phase shift of the reflection. The simplest cases, when the imaginary part of ρ is zero, are:

  • ρ = - 1 -- maximum negative reflection, when the line is short-circuited,
  • ρ = 0 -- no reflection, when the line is perfectly matched,
  • ρ = + 1 -- maximum positive reflection, when the line is open-circuited.

For the calculation of VSWR, only the magnitude of ρ, denoted by |ρ|, is of interest.


At some points along the line the two waves interfere constructively, and the resulting amplitude Vmax is the sum of their amplitudes:

.

At other points, the waves interfere destructively, and the resulting amplitude Vmin is the difference between their amplitudes:

.

The voltage standing wave ratio is then equal to:

, the absolute value of ρ, is used so that the VSWR is always greater than +1.


The SWR can also be defined as the ratio of the maximum amplitude of the electric field strength to its minimum amplitude, i.e. Emax / Emin.


Further analysis

To understand the standing wave ratio in detail, we need to calculate the voltage (or, equivalently, the electrical field strength) at any point along the transmission line at any moment in time. We can begin with the forward wave, whose voltage as a function of time t and of distance x along the transmission line is:

where A is the amplitude of the forward wave, ω is its angular frequency and k is a constant (equal to ω divided by the speed of the wave). The voltage of the reflected wave is a similar function, but spatially reversed (the sign of x is inverted) and attenuated by the reflection coefficient ρ:

.

The total voltage Vt on the transmission line is given by the principle of superposition, which is just a matter of adding the two waves:

.

Using standard trigonometric identities, this equation can be converted to the following form:

,

where .


This form of the equation shows, if we ignore some of the details, that the maximum voltage over time Vmot at a distance x from the transmitter is the periodic function

This varies with x from a minimum of A(1 - ρ) to a maximum of A(1 + ρ), as we saw in the earlier, simplified discussion. A graph of Vmot against x, in the case when ρ = 0.5, is shown below. Vmin and Vmax are the values used to calculate the SWR.

Standing wave ratio for ρ = 0.5
Standing wave ratio for ρ = 0.5

It is important to note that this graph does not show the instantaneous voltage profile along the transmission line. It only shows the amplitude of the oscillation at each point. The instantaneous voltage is a function of both time and distance, so could only be shown fully by a three-dimensional or animated graph.


Practical implications of SWR

SWR has a number of implications that are directly applicable to radio use.

  1. SWR is an indicator of reflected waves bouncing back and forth within the transmission line, and as such, an increase in SWR corresponds to an increase in power in the line beyond the actual transmitted power. This increased power will increase RF losses, as increased voltage increases dielectric losses, and increased current increases resistive losses.
  2. Matched impedances give ideal power transfer; mismatched impedances give high SWR and reduced power transfer.
  3. Higher power in the transmission line also leaks back into the radio, which causes it to heat up. This is a big concern for solid state radios, but the higher voltages associated with a sufficiently high SWR could cause tube radios to arc or the transmission line dielectric to break down.

References

  • Federal Standard 1037C and from MIL-STD-188
  • The ARRL Handbook chapter 19: "Transmission lines"
  • http://www.temcom.com/pages/dBCalc_manual.html
  • http://www.haefely.com/literature/pdf/emc/Cond_RF_Application_Note_01.pdf

  Results from FactBites:
 
Standing wave - Wikipedia, the free encyclopedia (308 words)
A standing wave, also known as a stationary wave, is a wave that remains in a constant position.
As an example of the second type, a standing wave in a transmission line is a wave in which the distribution of current, voltage, or field strength is formed by the superposition of two waves propagating in opposite directions.
The degree to which the wave resembles either a pure standing wave or a pure travelling wave is measured by the standing wave ratio (SWR).
Voltage standing wave ratio - definition of Voltage standing wave ratio in Encyclopedia (751 words)
In telecommunication, standing wave ratio (SWR) is the ratio of the amplitude of a partial standing wave at an antinode (maximum) to the amplitude at an adjacent node (minimum).
To understand the standing wave ratio in detail, we need to calculate the voltage (or, equivalently, the electrical field strength) at any point along the transmission line at any moment in time.
where A is the amplitude of the forward wave, ω is its angular frequency and k is a constant (equal to ω divided by the speed of the wave).
  More results at FactBites »


 

COMMENTARY     


Share your thoughts, questions and commentary here
Your name
Your comments
Please enter the 5-letter protection code

Want to know more?
Search encyclopedia, statistics and forums:

 


Lesson Plans | Student Area | Student FAQ | Reviews | Press Releases |  Feeds | Contact
The Wikipedia article included on this page is licensed under the GFDL.
Images may be subject to relevant owners' copyright.
All other elements are (c) copyright NationMaster.com 2003-5. All Rights Reserved.
Usage implies agreement with terms.